IMPROVE YOUR COMMUNICATION WITH AN ADVANCED IP PA SYSTEM TODAY

Improve Your Communication with an Advanced IP PA System Today

Improve Your Communication with an Advanced IP PA System Today

Blog Article

Network PA System for tool to massive tasks



Introduction


The XC-9000 system is a completely digital network PA system based on the TCP/IP method. By leveraging the TCP/IP procedure, the system guarantees the reliable and correct transmission of all information packages. Not just can it use existing local area network, such as LANs or the Net, to transmit broadcast signals, yet likewise it can likewise be released on a committed broadcasting network.


A single-server system can support up to 3000 terminals and allows for server plunging. There are no constraints on the concurrent program networks, attaining real full electronic broadcasting.


System Features



Versatile PA System Design


The PA system style is easy, consisting of service administration software program, network microphones, network amplifiers, network speakers, and various other devices.All devices is linked through the TCP/IP intranet protocol, permitting adaptable configuration and easy management of the system, with free control over broadcast material, network gadgets, and areas through the network.


Ip SpeakerIp Paging System
Comprehensive Sound Administration


The audio administration software application includes integrated functions for creating program plans, adaptable zoning, and pre-scheduled broadcasts.It sustains 24-hour programs, enabling transforming setups during all the time


Versatile Audio Source Assistance


The system sustains different forms of audio sources for sending notices like online speech and BGM playback. Audio resources can originate from digital musical apps, CD/DVD gamers, microphones, and so on. Furthermore, the system provides varied features of supporting various broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency broadcasting.


Emergency Alarm System Combination


The system has a smoke alarm feature and can be integrated right into an emergency alarm system. When the alarm system central device gets the alarming signals, the wire will send the signal to devices, which causes the XC-9000, sending out signals to audio speakers


Users can choose to pre-programmed settings to turn on full-area or zoned alarms in emergency situations. The alarm system voices can be found in numerous kinds and might be edited catering to demands. Users can transform language setups, upload and edit their audio resources according to exact requirements, such as intruding alarms, fire alarms or air help alarm systems, etc.


Fire Alarm System System Integration


The system has a smoke alarm function and can be integrated into a fire alarm system. When the alarm system central system obtains the startling signals, the cable will transmit the signal to devices, which sets off the XC-9000, sending out signals to speakers


Individuals could choose to predetermined setups to trigger full-area or zoned alarm systems in emergencies. The alarm system voices come in numerous kinds and can be modified satisfying demands. As an example, customers can transform language setups, upload and modify their audio sources according to precise demands, such as intruding alarm systems, emergency alarm or air aid alarm systems, etc





App Control for System Procedures


The system enables mobile app login and usage, enabling individuals to start broadcasts and other operations to accredited terminals via the server software application, making certain a practical and structured experience.


Integrated SIP Compatibility


The system not just enables SIP phones to log in, yet likewise can be linked to third-party SIP server or IPPBX, which develops a totally incorporated and suitable communication system through seamless assimilation into existing systems.


Open up SDK


When large job like smart park takes place, the system supplies an open SDK integrated into third-party application systems - IP Paging System


System Infrastructure



Main Functions


Set up Playback


The system has the ability to immediately broadcast according to the scheduled jobs as long as individuals submit the audio apply for each time duration of the day to the web server and produce a playback schedule.


Zone Broadcasting


The system can randomly divide a few network devices right into various areas to play specified audio programs or send out announcements to any kind of designated area. The quantity of each gadget can be remotely adjusted.


Real-time Broadcasting


The system can record and transmit radio programs or various other outside audio resources in real-time, and at the same time broadcast them in sync.


Emergency Alarm Combination


The system can be integrated with the fire alarm system for control. When a smoke alarm signal is caused, it immediately triggers the emergency situation program function and supports nearby floor alarms. It additionally permits hands-on emergency situation broadcasting by clicking a solitary switch.


SIP Phone Integration


The system can be integrated with SIP servers, allowing real-time speech of voice broadcasting via SIP phones to send out announcements anytime and anywhere.


CCTV Combination


The electronic devices such as IP POE Speakers embraces the global conventional ONVIF method, which enables their voices to be broadcast by means of VMS systems. The terminals can additionally be incorporated with CCTV systems for synchronized broadcast.


Main Products



Audio Management Software Application XC-9000


B/S style, sustains cross-platform applications.
Covers traditional broadcasting system functions, enabling dividers monitoring.
Unified monitoring of terminals within the system, viewing job status, and set volume change, etc.
Sustains building multi-level web server architectures, deploying management according to user geographical regions.
Offers SDK advancement bundles for secondary growth and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Procedures: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 18KHz.
Running Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Operating Temperature level: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Audio Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Frequency Action: 45Hz~ important site 18KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Feedback: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Dimensions: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 60Hz~ 18KHz.
Operating Temperature: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Area Mixing Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP User Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Protocol: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system results.
Operating Temperature level: -10~ 50 ℃.
Dimensions: 483x259x44mm.


Option For School





Adaptable Zoning Broadcast:


The completely network terminals can realize versatile zoning options, permitting relaying notifications to individual terminals or various zones ( devices).


Institution Bell System:


It gives school bell system at the beginning/ending of the class - IP Paging System. Numerous circumstances can be created, including different arranged broadcast tasks according to summer/winter timetable


Smoke Alarm Combination


It supports assimilation with fire alarm systems, enabling smoke alarm signals to be integrated right into the PA system.


Class Audio Amplification


Terminals support day-to-day applications in classroom scenes. They can be attached to projectors or interactive white boards for audio amplification.


Ip Pa SystemIp Paging Microphone

Smart Road Lamp/Security Pole



Support SIP Protocol:


Integrated SIP method for smooth integration with network interaction systems.


VMS Operatings Systems Integration:


Integrated ONVIF procedure for combination with VMS systems.


Third-Party Integration:


Integrated In HTTP API for combination with 3rd party platforms.


Voice Alarm System Activating:


Constructed in alarm input user interface for causing voice alarm systems with cameras.


Option For Resort



Zone Control by Flooring:


The system supplies full network settings, splitting areas counting on various floorings and control over each area separately.


Fire Alarm System Integration:


The system can be incorporated with smoke alarm system, enabling combination of fire alarm system discover this info here signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable scheduled broadcasting, enabling flexible arrangements according to different demands.


Emergency situation Broadcasting:


It sustains emergency broadcasting for the entire area, enabling one-click emergency situation communication.


Option For Factory



Zone Broadcasting:


It enables transmitting to any type of zone, guaranteeing no interference in between different locations.


Alarm system Triggering:


Terminals have different kinds of interfaces, allowing to trigger alarm systems when gotten in touch with cameras.


All Network Instruments:


Implementation of fully network gadgets significantly minimizes the trouble of operating such as inspecting tools on dangerous websites, and hence securing individuals and building.


The implementation of all network tools significantly minimizes the trouble of operation and upkeep administration


Integrated SIP Phones:


The system can be incorporated with SIP phone and broadcast notifications using SIP phones Our site any time and anywhere. Two-way audio talkback in between SIP phones and IP POE Speakers makes it easy for checking tools being in office or other offices.


The XC-9000 system is a totally digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP procedure, the system ensures the appropriate and effective transmission of all data packages. The system supports various kinds of audio sources for sending notices like online speech and BGM playback. In addition, the system offers varied features of supporting various broadcasting functions such as set up broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page